Shanghai Shiyin Photoelectric Instrument Co., Ltd

[email protected]

+86-21-58189111

high voltage and high frequency arthroscopy medical instrument for cartilage surgery

Radiofrequency-based

Radiofrequency-based arthroscopy in the ankle | Lower

MethodsSurgical TechniqueResultsDiscussionConclusiontrodes. 4,6 The high voltage . the use of RFE tools for arthroscopic treatment of cartilage lesion, analysing published studies presenting the clinical outcomes of this type of surgery…

(PDF)

(PDF) A review of current concepts in radiofrequency

Systems and methods are provided for applying a high frequency voltage in the presence of an electrically conductive fluid to create a relatively low-temperature plasma for ablation of tissue adjacent to, or in contact with, the plasma. In one embodiment, an electrosurgical probe or catheter is positioned adjacent the target site so that one or more active electrode(s) are …

US20040054366A1

US20040054366A1 - Instrument for electrosurgical tissue

 · Orthopedics | Synovial osteochondromatosis is a rare, benign, self-limiting condition characterized by formation of one or more cartilaginous or osteocartilaginous bodies by a synovial membrane in .

Joint

Joint Synovial Osteochondromatosis Following High-Voltage

trodes. 4,6 The high voltage . the use of RFE tools for arthroscopic treatment of cartilage lesion, analysing published studies presenting the clinical outcomes of this type of surgery…

Elbow

Elbow Arthroscopy: Procedure - Medical Health Tests

Medical instrument PT100B High Frequency Neurosurgery Electrosurgical Unit With CE Approved. US $560.00-$600.00 . High Voltage Surgery Instrument with Monopolar and bipolar DD-2. US $500.00-$2000 / Set. 1 Set . joint cartilage plasma electrosurgical probe of Surgical system / arthroscopy instruments for lateral release. US $100.00-$220.00 .

(PDF)

(PDF) A review of current concepts in radiofrequency

Systems and methods are provided for applying a high frequency voltage in the presence of an electrically conductive fluid to create a relatively low-temperature plasma for ablation of tissue adjacent to, or in contact with, the plasma. In one embodiment, an electrosurgical probe or catheter is positioned adjacent the target site so that one or more active electrode(s) are …

electrosurgical

electrosurgical instruments with ce, electrosurgical

In electrosurgery, high-frequency, alternating electric current at various voltages (200 to 10,000 V) is passed through the skin to generate heat. It requires a power supply and a handpiece with one or more electrodes. The device is controlled using a switch on the handpiece or a foot switch. Electrosurgery devices

US20040054366A1

US20040054366A1 - Instrument for electrosurgical tissue

[email protected] · www.tekno-medical.com ELECTRO SURGERY . Arthroscopy Arthroscopie Artroscopia Artroscopia ENDOSCOPY No. 210 Sinuskopie Sinuscopy Sinuscopie . Contact free, very high voltage, argon gas enhanced coagulation Accessory set tk 90011-50 see page 24 toM 212a

Electrosurgery

Electrosurgery | DermNet NZ

In most cases of fracture healing, electrical stimulation is performed through a process called capacitive coupling. In this process, two skin electrodes are placed on either side of the broken bone, and a low voltage battery passes a small current between the electrodes.

ELECTRO

ELECTRO SURGERY - TEKNO-MEDICAL

These included Harmonic s and RF bipolar computercontrolled vessel sealing devices and RF ablative energy instruments. 1,[5][6][7][16][17][18][19][21][22][23] PRINCIPLES OF EM SURGERY: COAGULATION AND CUTTING INSTRUMENTS ESES instruments pass a high-frequency AC current through tissue to cut, coagulate, desiccate, or fulgurate tissue. 1,5,6 .

Electrical

Electrical Stimulation to Accelerate Bone Healing

When studying high voltage, especially with Tesla coils, it is also important to examine the BEM high frequency effects that are also well-known. The average specific absorption rate (SAR) for a human body for example, is measured in watts/kilogram (W/kg) and has an increasing logarithmic dependence with frequency up until 1 gigahertz (1 GHz .

(PDF)

(PDF) Electromagnetic energy sources in surgery | Donna

The tissue to be treated is commonly dense and of high electrical impedance, such as meniscal cartilage. Output power and voltage settings reflect both the type of tissue, the size of electrode and the fact that arthroscopists are seeking a speed of effect comparable to the mechanical shaver devices they current employ, albeit from an electrode .

Tesla

Tesla High Voltage Electrotherapy - History and Science

During the ablation, high voltage is applied to the electrically conductive fluid . • A multi-functional instrument for arthroscopic interventions in the knee and shoulder area . Journal of Arthroscopic & Related Surgery, 21(7), 844-850. 4. Woloszko J, Stalder KR, Brown IG.

Electrosurgical

Electrosurgical instrument and an electrosurgical

Apparatus and methods for ablating, severing, cutting, shrinking, coagulating, or otherwise modifying a target tissue to be treated. In a method for treating a target tissue, an active electrode of an electrosurgical probe is positioned in at least close proximity to the target tissue in the presence of an electrically conductive fluid. A high frequency voltage is then applied …

Sinew

Sinew 50 - Lysistech GmbH

 · Junior physicians should ask more often for differential diagnostic assessment and let their decision be confirmed by senior physicians. There are high demands for training. The cartilage can be damaged from the instruments when inexperienced people carry out the procedure. Beginners need 2-3 times longer for this method than for open arthroscopy.

7,270,661

7,270,661 - Electrosurgical apparatus and methods for

 · Electromagnetic Energy Sources in Surgery Electromagnetic Energy Sources in Surgery Dubiel, Beata; Shires, Peter K.; Korvick, Donna; Chekan, Edward G. 2010-12-01 00:00:00 Electromagnetic (EM) energy‐based medical devices enable advances in oncology, endocrine, gynecology, urology, and general surgery. Laser, microwave, Harmonic ® , high …

Minimally

Minimally invasive surgery in the Federal Republic of

The voltage and current generated by the voltage generator 516 may be delivered in a series of voltage pulses or AC voltage with a sufficiently high frequency (e.g., on the order of 5 kHz to 20 MHz) such that the voltage is effectively applied continuously (as compared with, e.g., lasers claiming small depths of necrosis, which are pulsed about .

Electromagnetic

Electromagnetic Energy Sources in Surgery, Veterinary

MethodsSurgical TechniqueResultsDiscussionConclusiontrodes. 4,6 The high voltage . the use of RFE tools for arthroscopic treatment of cartilage lesion, analysing published studies presenting the clinical outcomes of this type of surgery…

US

US Patent for System and method of an electrosurgical

MethodsSurgical TechniqueResultsDiscussionConclusiontrodes. 4,6 The high voltage . the use of RFE tools for arthroscopic treatment of cartilage lesion, analysing published studies presenting the clinical outcomes of this type of surgery…